The compressor operates in all events except the system air
filling and two solenoid valves (referred to as reverse valve, on-off
control, and normal open) are embedded.
Air dryer is maintenance free (permanent use).The relief
valve opens upon the pressure of 20±3bar.The compressor relay is
monitored by control module in order to detect any failure in relay. If
the compressor relay is failed (short to battery, short to ground or
open circuit), the lifting is prohibited but down leveling is only
available. However, the down leveling is done not by compressor but
ambient valve.
Components
1. Dyer2. Motor3. Connected to tube4. Reverse valve connector5. Connector for motor driveing
...
Circuit diagram
1.
Air compressor connector
[Motor power connector (A)][Exhaust valve connector (B)][Temperature sensor connector (C)]
2.
Air compressor terminal function
[Motor power]
...
See also:
How does the air bag system operate
Air bags are activated (able to inflate if necessary) only when the Engine
Start/Stop Button is turned to the ON or START position.
Air bags inflate in the event of a severe frontal or side co ...
Starter Repair procedures
Removal
1.
Turn ignition switch OFF and disconnect the negative (-) battery cable.
2.
Disconnect the starter cable (A) from the B terminal on the solenoid, and the connector (B) from the S ter ...
Underdrive Brake Control Solenoid Valve(UD/B_VFS) Specifications
Specifications
Direct control VFS[UD/C]
x Control type : Normal low type