1. |
Turn the ignition switch OFF. |
2. |
Disconnect the OCV connector. |
3. |
Measure resistance between the OCV terminals 1 and 2. |
4. |
Check that the resistance is within the specification.
Specification: Refer to “Specification”
|
|
[CVVT Oil Control Valve (Bank 1)]
1. |
Turn ignition switch OFF and disconnect the negative (-) battery cable. |
2. |
Disconnect the CVVT oil control valve connector (A-Intake) and (B-Exhaust). |
3. |
Remove the mounting bolt, and then remove the valve from the engine. |
[CVVT Oil Control Valve (Bank 2)]
1. |
Turn ignition switch OFF and disconnect the negative (-) battery cable. |
2. |
Disconnect the CVVT oil control valve connector (A-Intake) and (B-Exhaust). |
3. |
Remove the mounting bolt, and then remove the valve from the engine. |
1. |
Installation is the reverse of removal.
CVVT oil control valve installation bolt:
9.8 ~ 11.8 N.m (1.0 ~ 1.2 kgf.m, 7.2 ~ 8.7 lb-ft)
|
Pay attention to color of valve connector (Harness side) when installing.
If an OCV is installed on opposite manifold, the engine may be damaged. |
[Connector Color]
Item
| Component Side
| Harness Side
| Intake
| Black
| Gray
| Exhaust
| Black
| Black
|
|
Description
Fuel Pressure Control Valve is installed on the high pressure
fuel pump and controls fuel flow flowing into the injectors in
accordance with the ECM signal calculated based on vario ...
See also:
Ignition Coil Specifications
Specification
ItemSpecification Primary Coil Resistance (x)0.62 ± 10% [20°C (68°F)]Secondary Coil Resistance (kx)7.0 ± 15% [20°C (68°F)]
...
Rolling code programming
Rolling code devices which are "code-protected" and manufactured after 1996 may
be determined by the following:
Reference the device owner's manual for verification.
The handheld ...
Mode Control Actuator Repair procedures
Inspection
1.
Turn the ignition switch OFF.
2.
Disconnect the mode control actuator connector.
3.
Verify that the mode control actuator operates to the defrost mode when connecting 12V to ...