To operate, simply press and release the programmed HomeLink® button. Activation will now occur for the trained device (i.e. garage door opener, gate operator, security system, entry door lock, home/office lighting, etc.). For convenience, the hand-held transmitter of the device may also be used at any time.
Specifications
Specifications
ItemsSpecificationsRated voltage5VLoadMax. 1mA (Relay load)Detection illuminationsTail lampON : 74 ± 16 (Lux), 2.36 ± 0.08 (V)OFF : 148 ± 32 (Lux), 4.52 ± 0.1 (V)Head lampON : 18.5 ...
Evaporator Temperature Sensor Repair procedures
Inspection
1.
Turn the ignition switch OFF.
2.
Disconnect the evaporator temperature sensor connector.
3.
Measure the resistance between terminal “+” and “-” of the evaporator temperature ...
Oil Pump Description and Operation
Description
The oil pump rotation builds the hydraulic pressure needed
for the lubrication of the various parts of the automatice transmission
and operation of the clutch and brakes.
The oil ...