Inspection |
1. |
Disconnect the negative (-) battery terminal. |
2. |
Remove the rear glass defogger relay (A) from the engine room relay box. |
3. |
There should be continuity between the No.87 and No.30
terminals when power and ground are connected to the No.86 and No.85 in
the relay. |
4. |
There should be no continuity between the No.87 and No.30 terminals when power is disconnected. |
Tilt & Telescope Control (SCM) Description and Operation
Description
The Tilt & Telescope operation function in SCM contains of the following function.
1.
Manual control with direction switches (Tilt Up/Down, Telescope Forward/Backward).
2.
Pla ...
Rail Pressure Sensor (RPS) Troubleshooting
Signal Waveform
...
Thermostat Troubleshooting
Troubleshooting
SymptomsPossible CausesRemedyCoolant leakage
•
From the thermostat gasket
Check the mounting bolts
•
Check the torque of the mounting bolts
•
Retighten the bolts an ...