Inspection |
1. |
Turn ignition switch OFF. |
2. |
Disconnect the E Module connector. |
3. |
Measure resistance between sensor signal terminal and sensor ground terminal. |
4. |
Check that the resistance is within the specification.
|
Removal |
1. |
Draining ATF totally.
(Refer to Hydraulic system - "Fluid") |
2. |
Disconnector the E-Module connector (A).
|
3. |
Remove the oil pan (A).
|
4. |
Remove the valve body assembly (A). |
5. |
Disconnect the pressure switch connector (A). |
6. |
Remove the pressure switch (A).
|
Installation |
1. |
Install in the reverse order of removal.
|
LCD Display Control
The LCD display modes can be changed by using the control buttons on the steering
wheel.
(1) button : Changing LCD modes
(right to left), or returning to previous position
(2) button : Chan ...
Repair procedures
Inspection
1.
After disconnecting the vapor hose from the PCV valve, remove the PCV valve.
2.
Reconnect the PCV valve to the vapor hose.
3.
Run the engine at idle, and put a finger on t ...
Side repeater light bulb replacement (if equipped)
If the light bulb is not operating, have the vehicle checked by an authorized
EQUUS dealer. ...