Specifications |
Items | Specification |
Air spring volume at design position | 1.78x |
Maximum other bellow diameter | 118 mm |
Burst pressure | 31.5 bar |
Minimum operating temperature | -40°C |
Maximum operating temperature | 80°C |
Items | Specification |
Operation voltage | 9 ~ 15 VDC |
Max. perm. Current | 35 A Min |
Lower operation temperature | -40°C |
Upper operation temperature | 70°C |
Storage Temperature | -40°C ~ 90°C |
Items | Specification |
Operation voltage | 9 ~ 15 VDC |
Lower operation temperature | -40°C |
Upper operation temperature | 70°C |
Storage Temperature | -40°C ~ 90°C |
Items | Specification |
Required supply voltage | 5 VDC 5% |
Operation voltage | 5 VDC 10% |
Maximum allowed voltage range | 20 V |
Storage Temperature | -40°C ~ 90°C |
Items | Specification |
Operating pressure | 16.5 bar |
Burst pressure | 40 bar min |
Air tank volume | 5.2 x |
Items | Specification |
Rated Voltage | 12 V DC |
Operating Voltage | 10 ~ 16 V DC |
Operation Temperature | -40°C ~ 75°C |
Storage Temperature | -40°C ~ 90°C |
Item | Tightening torque (kgf.m) | ||
N.m | kgf.m | lb-ft | |
Reservoir tank to crash box | 17.0 ~ 26.0 | 1.7 ~ 2.6 | 12.0 ~ 19.0 |
Reservoir tank to frame housing | 20.0 ~ 30.0 | 2.0 ~ 3.0 | 14.0 ~ 22.0 |
Front height sensor to frame | 17.0 ~ 26.0 | 1.7 ~ 2.6 | 12.0 ~ 19.0 |
Front height sensor to lateral arm | 17.0 ~ 26.0 | 1.7 ~ 2.6 | 12.0 ~ 19.0 |
Solenoid valve to bracket | 8.0 ~ 12.0 | 0.8 ~ 1.2 | 6.0 ~ 9.0 |
Compressor to bracket | 8.0 ~ 12.0 | 0.8 ~ 1.2 | 6.0 ~ 9.0 |
G-sensor to frame | 4.0 ~ 6.0 | 0.4 ~ 0.6 | 3.0 ~ 4.0 |
Compressor & bracket to frame crash box | 35.0 ~ 55.0 | 3.5 ~ 5.5 | 25.0 ~ 40.0 |
Air filter to frame | 4.0 ~ 6.0 | 0.4 ~ 0.6 | 3.0 ~ 4.0 |
Front height sensor to frame | 4.0 ~ 6.0 | 0.4 ~ 0.6 | 3.0 ~ 4.0 |
Feeling valve mounting bracket to frame | 17.0 ~ 26.0 | 1.7 ~ 2.6 | 12.0 ~ 19.0 |
Reservoir Tank Description and Operation
Description
The volume is 5.2 liter and the maximum operation pressure is 16bar. (Bursting pressure: 40bar)
The pressure of reservoir tank is monitored every 30 min while driving. ...
Front Lower Arm Repair procedures
Removal
Remove the lateral arm.
1.
Remove the front wheel and tire (A) from front hub .
Tightening torque:
88.3 ~ 107.9 N.m (9.0 ~ 11.0 kgf.m, 65.1 ~ 79.6 lb-ft)
•
...
Front Area Module(FAM) Description and Operation
Description
FAM (Front Area Module)
The FAM includes the functions for the following list :
-
Wiper control (Rain sensor communication and transfer Rain sensor request information to Wiper modu ...