Removal |
1. |
Disconnect the vapor hose (A). |
2. |
Remove the PCV valve (B). |
Inspection |
1. |
Insert a thin stick (A) into the PCV valve (B) from the threaded side to check that the plunger moves.
|
Installation |
1. |
Installation is reverse of removal.
|
Intake Actuator Repair procedures
Inspection
1.
Turn the ignition switch OFF.
2.
Disconnect the intake actuator connector.
3.
Verify that the intake actuator operates to the fresh position when connecting 12V to terminal 3 ...
Trunk Lid Assembly Components and Components Location
Component Location
1. Trunk lid assembly
...
Turn signals and lane change signals
The ignition switch must be on for the turn signals to function. To turn on the
turn signals, move the lever up or down (A). Green arrow indicators on the instrument
panel indicate which turn ...