The compressor operates in all events except the system air
filling and two solenoid valves (referred to as reverse valve, on-off
control, and normal open) are embedded.
Air dryer is maintenance free (permanent use).The relief
valve opens upon the pressure of 20±3bar.The compressor relay is
monitored by control module in order to detect any failure in relay. If
the compressor relay is failed (short to battery, short to ground or
open circuit), the lifting is prohibited but down leveling is only
available. However, the down leveling is done not by compressor but
ambient valve.
Components
1. Dyer2. Motor3. Connected to tube4. Reverse valve connector5. Connector for motor driveing
...
Circuit diagram
1.
Air compressor connector
[Motor power connector (A)][Exhaust valve connector (B)][Temperature sensor connector (C)]
2.
Air compressor terminal function
[Motor power]
...
See also:
Specifications
Specifications
ItemSpecificationFront/Rear parking assist system control unitRated voltageDC 12VOperation range30~120 cm(11.8~47.2 in)Operation voltageDC 9V~16VOperation currentMax. 300 mAOperati ...
Climate Seat Unit Description and Operation
Description
Comparing with the seat heat function by the existing thermic
rays, Climate Control Seat functions the heating,cooling, dehumidifying
by using TED.
It inhales the indoor air throug ...
Warning type
The system will activate when:
1.The system is on
2.Vehicle speed is above 9.3 mph (15 km/h)
3.Other vehicles are detected in the rear side