Hyundai Equus: Compressor Description and Operation
The compressor operates in all events except the system air
filling and two solenoid valves (referred to as reverse valve, on-off
control, and normal open) are embedded.
Air dryer is maintenance free (permanent use).The relief
valve opens upon the pressure of 20±3bar.The compressor relay is
monitored by control module in order to detect any failure in relay. If
the compressor relay is failed (short to battery, short to ground or
open circuit), the lifting is prohibited but down leveling is only
available. However, the down leveling is done not by compressor but
ambient valve.
Components
1. Dyer2. Motor3. Connected to tube4. Reverse valve connector5. Connector for motor driveing
...
Circuit diagram
1.
Air compressor connector
[Motor power connector (A)][Exhaust valve connector (B)][Temperature sensor connector (C)]
2.
Air compressor terminal function
[Motor power]
...
See also:
Front Pillar Trim Repair procedures
Replacement
•
Put on gloves to protect your hands.
•
When prying with a flat-tip screwdriver, wrap it with
protective tape, and apply protec ...
Sunroof Glass Repair procedures
Replacement
•
Put on glove to protect your hands.
1.
Remove both sides of the decoration cover (A).
2.
Loosen the mounting screws, then remove the glass (A) by l ...
ESP OFF Switch Description and Operation
Description
1.
The ESP OFF switch is for the user to turn off the ESP system.
2.
The ESP OFF lamp is on when ESP OFF switch is engaged. ...