Removal |
1. |
Disconnect the negative (-) battery terminal. |
2. |
Detach the lamp lens and reflector (A) from the room lamp with a flat-tip screwdriver. |
3. |
Remove the room lamp (A) after removing the screws. |
4. |
Replace the room lamp after removing the connectors (A). |
1. |
Disconnect the negative (-) battery terminal. |
2. |
Remove the lens (A) using a flat-tip screwdriver. |
3. |
Remove the vanity lamp (A) after loosening the mounting screws. |
4. |
Remove the vanity lamp assembly after disconnecting the connector (A). |
Installation |
1. |
Connect the connector and install the room lamp. |
2. |
Install the lamp reflector and lamp len. |
1. |
Install the vanity lamp. |
2. |
Install the lens. |
Inspection |
1. |
Check "IPM" input/output specification of room lamp using the GDS. |
2. |
Select option "Input/output monitoring". |
3. |
Select option "Actuation Test" to perform functional test. |
Power Seat Motor Repair procedures
Inspection
Slide Motor Limit Switch
1.
Disconnect the limit switch (A) and operate the limit switch.
2.
Check for continuity between the terminals.
3.
Make sure that the seat operation is ...
Fuel Pressure Control Valve Troubleshooting
Signal Waveform
...
Injector Drive Box (IDB) Repair procedures
Remove
1.
Turn ignition switch OFF and disconnect the negative (-) battery cable.
2.
Remove the IDB cover (A).
3.
Disconnect the IDB Connector (A).
4.
Remove the mounting bolts (B), an ...