Specifications |
Items | Specification |
Rated voltage | DC 12V |
Operating voltage | DC 9 ~ 16V |
Operating temperature | -22°F ~ 167°F (-30°C ~ 75°C) |
Load | Max. 2.5 mA (When welcome function 3.7 mA) |
Items | Specification |
Frequency | 433.92 Mhz |
Antenna type | FSK (Frequency Shift Keying) |
Items | Specification | |||||
Fob key | Card key | |||||
Battery | Lithium battery 3V 1EA (CR2032) | Lithium battery 3V 1EA (CR2412) | ||||
Distance | 30m from vehicle (RF) : 30m, Passive(LF) : 0.7m | Passive(LF) : 0.7m | ||||
Battery life | More than 2 years (10 times / a day)
| |||||
Push buttons | 4 (Door lock / unlock, Tailgate, Panic) | - | ||||
Frequency(Rx) | 125 kHz | |||||
Frequency(Tx) | 433.92 MHz | |||||
Numbers | 2EA (Fob 2EA or Fob 1EA + Card 1EA) |
Items | Specification |
Rated voltage | DC 12V |
Operating voltage | DC 9 ~ 16V |
Operating temperature | -22°F ~ 167°F (-30°C ~ 75°C) |
Frequency | 125 kHz |
Numbers | Interior(4EA), Door(4EA), Bumper(1EA) |
Emergency Fastening Device (EFD) Description and Operation
Description
The Emergency Fastening Device (EFD) operates at the same
time with the Seat Belt Pretensioner when it satisifies the deployment
condition after a collision. It is an auxiliary equi ...
Water pump Troubleshooting
Troubleshooting
Water Pump
SymptomsPossible CausesRemedyCoolant leakage
•
From the bleed hole of the water pump
Visually check
•
Check leaks after about ten-minute warming up.
•
If ...
Erasing HomeLink® buttons
Individual buttons cannot be erased. However, to erase all three programmed buttons:
1. Press and hold the two outer HomeLink® buttons until the indicator light begins
to flash-after 20 seconds.