The cluster ion generator makes disinfection and
decomposition of bad smell from the air-conditioner or inflow air. And
it cleans the inside air of a vehicle.
When the ignition switch is ON, the generator activates "CLEAN" mode and then "ION" mode, switching between both modes.
In the “CLEAN” mode, the cluster ion generator generates negative ions and positive ions to help clean smells from the air.
In the “ION” mode, the cluster ion generator generates negative ions and cleans inside air of a vehicle.
Inspection
To inspect and diagnose the sensor, refer to Self-Diagnosis procedure and DTC guide.
Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Using a screwdriver or remov ...
Inspection
1.
Press the MODE switch more then 4 times within 2 seconds while pressing the OFF switch.
DisplayFail description00Normal51Cluster ion generator fault
* For diagnostic procedur ...
See also:
Starting the engine
WARNING
Always wear appropriate shoes when operating your vehicle. Unsuitable shoes
(high heels, slippers, ski boots, etc.) may interfere with your ability to use the
brake and accelerator pedal. ...
Front Strut Assembly Repair procedures
Removal
1.
Remove the front wheel and tire (A) from front hub .
Tightening torque:
88.3 ~ 107.9 N.m (9.0 ~ 11.0 kgf.m, 65.1 ~ 79.6 lb-ft)
•