>
Inspection |
1. |
Turn the ignition switch OFF. |
2. |
Disconnect the PCSV connector. |
3. |
Measure resistance between the PCSV terminals 1 and 2. |
4. |
Check that the resistance is within the specification.
|
Removal |
1. |
Turn the ignition switch OFF and disconnect the battery negative (-) cable. |
2. |
Disconnect the purge control solenoid valve connector (A). |
3. |
Disconnect the vapor hose (B) from the purge control solenoid valve. |
4. |
Remove the valve after removing the bolt (C). |
Installation |
|
|
1. |
Install in the reverse order of removal.
|
Head Up Display Unit Schematic Diagrams
Circuit Diagram
...
Solenoid Valve Description and Operation
Description
Four air spring solenoid valves (‘-’ control) and one
ambient solenoid valve are embedded inside this solenoid valve block as
shown in the circuit diagram below. When connecting the ...
Description and Operation
Description
Burglar Alarm State [B/A State]
B/A StateDescriptionDISARM
1.
In "DISARM" state, no vehicle start inhibition. So, when
door, hood, or Tailgate is opened, there is no alarm sound ...